What is the 100-metre or 328-foot Ethernet distance limit?

For standards-based twisted-pair Ethernet, the complete channel is designed for up to 100 metres (328 feet), including patch and equipment cords. The fixed installed cable—the permanent link—is normally limited to 90 metres, leaving up to 10 metres for cords. Measure the actual cable route, not the straight-line distance between rooms.

Published: November 16, 2026Updated: November 16, 20262 min read

What counts toward the 100 metres

Count the cable from the patch panel to the wall outlet plus the patch cords used at the equipment and device ends. A common design is a 90-metre permanent link with a five-metre cord at each end, although detailed cord allowances depend on the channel design.

The routed length includes vertical drops, service loops and detours around framing or ductwork. Two rooms that look close on a floor plan can have a much longer cable path between them.

Permanent link and channel are different tests

A permanent-link test covers the fixed cable and its installed terminations. A channel test also includes the cords that will be used in service. Ask which configuration appears on a test report so the result is meaningful.

Do not treat a tester’s length estimate as permission to exceed the design limit. Length measurement has uncertainty, and other parameters such as insertion loss still have to pass.

Does Cat6A change the distance?

Cat6A supports 10GBASE-T to the full 100-metre channel under the standard assumptions; it does not remove the 100-metre boundary. Cat6 supports gigabit Ethernet to 100 metres, while its 10-gigabit reach is shorter and depends on the installed environment.

Higher cable categories also do not make a badly terminated or damaged long run reliable. The complete channel, including jacks and cords, must meet the intended performance level.

What to do when the route is too long

Use fiber for a long backbone or between buildings, or place properly powered active equipment at a suitable intermediate location. Purpose-built extenders are another option when their speed, power and environmental limits fit the job.

A passive coupler does not reset the Ethernet distance budget. Neither does adding a second patch cord or switching to a more expensive category of copper cable.

Leave margin in the design

Plan well below the maximum when the route is uncertain, temperatures are high, or PoE bundles add design constraints. Record the planned route and confirm the installed result with the appropriate test rather than discovering the length after equipment is connected.

Sources and further reading

Best for

Planning long runs, outbuilding links or a central equipment location.

Things to consider

  • 100 metres includes cords
  • The permanent link is normally 90 metres
  • Measure the route rather than the floor plan

Common mistakes

  • Using a coupler to reset the distance
  • Assuming Cat6A removes the limit

What we recommend

Leave margin below 100 metres and use fiber or properly placed active equipment for longer pathways.